XGW-12 Box-type Switching Station(Ring Main Unit)

Short Description:


Product Detail

Product Tags

Product Overview

10KV outdoor switching station, mainly used in the power supply and distribution system with rated voltage of 12kV and rated frequency of 50Hz, has the function of connecting, transferring and distributing electric energy. The equipment has the advantages of excellent performance, standard design, beautiful appearance, corrosion resistance, small volume, safe and reliable, compact structure, flexible and convenient. It can be operated by electric or manual, and can realize the “three remote” functions of remote control, telemetry and remote signaling, and improve the reliability of power supply. It is widely used in urban power grid reconstruction, residential area, commercial center and other urban densely populated areas.

Type Description

rth

Functions and Features

● Adopt Prefabricated live touch silicone rubber cable head, fully sealed, fully insulated, maintenance free, reliable to ensure personal safety;

● Compact structure, small and beautiful appearance, stainless steel double-layer box, the service life can reach more than 20 years;

● On the premise of not affecting the operation of the main network, the regional outage maintenance is realized to reduce the scope of power outage;

● It can be equipped with one or more SF6 load switches. The connection method is flexible and diverse, and the branch outlet can reach up to 8 loops at most;

● Optional arrester, short-circuit fault indicator, current limiting fuse, etc., to meet the requirements of users.

Main Technical Parameters

Name

Value

Rated voltage

12kV

Rated current

630A

Power frequency withstand voltage (phase-to-earth)

42kV/1min

Lightning impulse withstand voltage

75kV

Rated breaking current

630A

Rated short circuit making current (peak)

50kA

Rated short time withstand current

25kA/4s

Rated peak withstand current

50kA

Rated breaking capacitor current

45A

Rated breaking inductive current

16A

Breaking time at full load

>100

Breaking and making mechanical operation number

2000

Wiring Method

Model

Line number description

Primary wiring diagram

Overall dimensions (L*W*H)

XGW-102K

1 incoming, 2 branches, with 1 switch

 htr (1)

1180×1050×1600

XGW-103K

1 incoming, 3 branches, with 1 switch

 htr (2)

1250×1050×1600

XGW-104K

1 incoming, 4 branches, with 1 switch

 htr (3)

1250×1050×1600

XGW-112K

1 incoming, 1 outgoing, 2 branches, with 1 switch

 htr (4)

1350×1050×1600

XGW-113K

1 incoming, 1 outgoing, 3 branches, with 1 switch

 htr (5)

1420×1050×1600

XGW-114K

1 incoming, 1 outgoing, 4 branches, with 1 switch

 htr (6)

1420×1050×1600

XGW-102K2

1 incoming, 2 branches, with 2 switch

 htr (7)

1350×1050×1600

XGW-112K2

1 incoming, 1 outgoing, 2 branches, with 2 switches

 htr (8)

1500×1050×1600

XGW-103K3

1 incoming, 3 branches, with 3 switches

 htr (9)

1850×1050×1600

XGW-113K3

1 incoming, 1 outgoing, 3 branches, with 3 switches

 htr (10)

2000×1050×1600

Note: The user can choose lightning arrester, known path fault indicator, fuse, etc.

Overall Dimensions

ht (1)

ht (6)

Examples of Common Solutions

XGW-102K

switchgear

1

Type

HXGN-12

Dimensions: W*D*H

375X950X1400

Scheme wiring diagram

ht (4)

Main components Application

Incoming

Outgoing

Outgoing

SF6 load break switch LN36-12/630-20

1

European type double-pass bushing 630A

3

Arrester HY5WS-17/50

3

Charged display GSN-10/T

1

Cable front connector
Cable rear connector

240mm2

150mm2

XGW-103K

switchgear

1

Type

HXGN-12

Dimensions: W*D*H

375X950X1400

Scheme wiring diagram

 tr

Main components Application

Incoming

Outgoing

Outgoing

Outgoing

SF6 load break switch LN36-12/630-20

1

European type double-pass special shape busbar CEEYMP2A-Z-10/630

3

Arrester HY5WS-17/50

3

Charged display GSN-10/T

1

Cable front connector

240mm2

150mm2

70mm2

Cable rear connector

Cable Connection Section View

 ht (3)

Overall Dimensions

ht (2)

Order to know

The primary diagram can be provided if the user has special requirements and model number.

Standard section of incoming and outgoing cables and branch cables.

The number of optional arresters and short circuit fault indicators.

Enclosure material and color.


  • Previous: