Assume full accountability to meet all requires of our purchasers; realize continual advancements by selling the advancement of our customers; grow to be the final permanent cooperative partner of consumers and maximize the interests of clientele for Hot sale Factory China Sealed Indoor AC High Voltage Vacuum Circuit Breaker 10kv 11kv 24kv (vcb), We are able to customize the merchandise according in your prerequisites and we will pack it in your case when you purchase.
Assume full accountability to meet all requires of our purchasers; realize continual advancements by selling the advancement of our customers; grow to be the final permanent cooperative partner of consumers and maximize the interests of clientele for China Vacuum Circuit Breaker, Vcb, With a wide range, good quality, reasonable prices and stylish designs, our merchandise are extensively used in public placesand other industries. Our solutions are widely recognized and trusted by users and can meet continuously developing economic and social needs. We welcome new and old customers from all walks of life to contact us for future business relationships and achieving mutual success!
VS1-12 indoor HV vacuum circuit breaker is a 3-phase AC 50Hz 12kV indoor switch equipment.
♦ Installation way: withdrawable type, fixed type, side mounted type;
♦ Operating mechanism: spring ope rating mechanism, permanent magnetic operating mechanism;
♦ Pole type: assembled pole, embedded pole;
♦ Application: switchgear KYN28-12, XGN-12.
♦ Secondary plug: 58pins, 64pins.
Product Standards
♦ IEC62271-100 High Voltage Switchgear and Controlgear Part 100: AC Circuit-breakers
♦ GB1984 High Voltage AC Circuit-breakers
♦ GB/T11022 Common Specifications for High-voltage Switchgear and Controlgear Standards
♦ JB/T 3855 High Voltage AC Vacuum Circuit-breakers
♦ DL/T402 Specification of High-voltage AC Circuit-breakers
Environmental Conditions
♦ Ambient temperature: -15°C~+40°C;
♦ Altitude: <1000m;
♦ Relative humidity: daily average <95%, monthly average <90%;
♦ Earthquake intensity: <8 level;
♦ Places without fire, explosion hazard, serious filthy, chemical corrosion, as well as intense vibration.
Main Technical Parameters
No |
Item |
Unit |
Value |
1 | Rated voltage | kV |
12 |
2 | 1 min power frequency withstand voltage |
42 |
|
3 | Rated lightning impulse withstand voltage |
75 |
|
4 | Rated frequency | Hz |
50 |
5 | Rated current | A |
630, 1250, 1600, 2000, 2500, 3150, 4000 |
6 | Rated short circuit breaking current | kA |
20, 25, 31.5, 40 |
7 | Rated short time withstand current |
20, 25, 31.5, 40 |
|
8 | Rated short circuit duration | s |
4 |
9 | Rated peak value withstand current |
kA |
50, 63, 80, 100 |
10 | Rated short circuit making current |
50, 63, 80, 100 |
|
11 | Secondary circuit power frequency withstand voltage (1min) | V |
2000 |
12 | Rated single / back-to-back capacitor bank breaking current | A |
630/400 (800/400 for 40kA and 50kA) |
No |
Item |
Unit |
Value |
13 |
Rated capacitor bank closing inrush current | A |
12.5 |
14 |
Opening time (rated voltage) |
ms |
20-50 |
15 |
Closing time (rated voltage) |
ms |
35-70 |
16 |
Mechanical life |
Times |
10000 |
17 |
Rated current breaking number |
Times |
10000 |
18 |
Rated short circuit current breaking number |
Times |
50 (30 for 40kA; 20 for 50kA) |
19 |
Moving and fixed contacts cumulative allowed wear thickness | mm |
3 |
20 | Rated closing operating voltage | V |
AC/DC110/220 |
21 | Rated opening operating voltage | ||
22 | Rated voltage of energy storage motor |
W |
70 (80 ror 40kA and 50kA) |
23 | Rated power of energy storage motor | ||
24 | Energy storage time | s |
<10 |
25 | Clearance between open contacts | mm |
11±1 |
26 | Over travel | mm |
3.5±0.5 |
27 | Contact closing bounce time | ms |
≤2 (≤3 for 40kA and 50kA) |
28 | Three phase opening and closing asynchronism | ms |
≤2 |
29 | Average opening speed |
m/s |
0.9-1.2 |
30 | Average closing speed |
m/s |
0.5-0.8 |
31 | Main conductive circuit resistance | μΩ |
≤60 (630A) ≤50(1250A) ≤35(1600-2000A) ≤25(above 2500A) |
32 | Closing contact pressure of the contacts | N |
2000±200 (20kA) 2400±200 (25kA) 3100±200 (31.5kA) 4250±250 (40kA) 6500±500 (50kA) |
33 | Rated operating sequence |
O-0.3s-CO-180s-CO O-180s-CO-180s-CO (50kA) |
Note: when current is 4000A or 5000A, need forced air cooling.
General Structure Drawing and Installation Size (unit: mm)
♦ Draw out type
Cabinet width |
Rated current (A) |
Rated short circuit breaking current (kA) |
P | H |
A |
B |
C |
D |
E | F |
G |
J |
K |
L |
M |
N |
R |
S |
T |
650 | 630 |
20 〜31.5 |
150 | 275 | 490 | 502 | 492 |
500 |
433 | 626 |
035 |
280 | 598 | 76 | 78 | 637 | 508 | 202 | 40 |
650 | 1250 |
20 〜31.5 |
150 | 275 | 490 | 502 | 492 |
500 |
433 | 626 |
049 |
280 | 598 | 76 | 78 | 637 | 508 | 202 | 40 |
800 | 630 |
20 〜31.5 |
210 | 275 | 638 | 652 | 640 |
650 |
433 | 626 |
035 |
280 | 598 | 76 | 78 | 637 | 508 | 277 | 40 |
800 | 1250 |
20-40 |
210 | 275 | 638 | 652 | 640 |
650 |
433 | 626 |
049 |
280 | 598 | 76 | 78 | 637 | 508 | 277 | 40 |
800 | 1600 |
31.5〜40 |
210 | 275 | 638 | 652 | 640 |
650 |
433 | 626 | 055 | 280 | 598 | 76 | 78 | 637 | 508 | 277 | 40 |
1000 | 630 |
20 〜31.5 |
275 | 275 | 838 | 852 | 838 |
850 |
433 | 626 |
035 |
280 | 598 | 76 | 78 | 637 | 508 | 377 | 40 |
1000 | 1250 |
20 〜40 |
275 | 275 | 838 | 852 | 838 |
850 |
433 | 626 |
049 |
280 | 598 | 76 | 78 | 637 | 508 | 377 | 40 |
1000 | 1600 |
31.5-40 |
275 | 275 | 838 | 852 | 838 |
850 |
433 | 626 |
055 |
280 | 598 | 76 | 78 | 637 | 508 | 377 | 40 |
1000 | 1600-2000 |
31.5 〜40 |
275 | 310 | 838 | 852 | 838 |
850 |
361 | 680 |
079 |
295 | 586 | 77 | 88 | 698 | 536 | 377 |
0 |
1000 | 2500〜4000 |
31.5 〜40 |
275 | 310 | 838 | 852 | 838 |
850 |
361 | 680 |
0109 |
295 | 586 | 77 | 88 | 698 | 536 | 377 |
0 |
♦ Fixed type
Cabinet width |
Ra»a current (A) |
P |
H |
A |
C |
E |
G1 |
J |
K |
L |
650 |
630-1600 |
150 |
275 |
385 |
440 |
580 |
I |
237 |
455 |
395 |
800 |
630-1600 |
210 |
275 |
520 |
588 |
580 |
II |
237 |
455 |
410 |
1000 |
630~1600 |
275 |
275 |
720 |
770 |
580 |
II |
237 |
455 |
410 |
1000 |
1600~4000 |
275 |
310 |
720 |
770 |
632 |
III |
252 |
465 |
440 |
♦ Side mounted type
We rely upon strategic thinking, constant modernisation in all segments, technological advances and of course upon our employees that directly participate inside our success for Professional Design China (ZN63A) VS1-12 (12kV/1250A-25kA) High Voltage Withdrawable Type Insulating Cylinder Type Vacuum Circuit Breaker for Swithchgear, On account of superior high quality and competitive value , we’ll be the sector leader, make sure you don’t hesitate to make contact with us by cell phone or email, should you be intrigued in any of our products and solutions.
Professional Design China 12kV Indoor Vacuum Circuit Breaker, Medium Voltage Vcb with Insulating Cylinder, By integrating manufacturing with foreign trade sectors, we can offer total customer solutions by guaranteeing the delivery of right items to the right place at the right time, which is supported by our abundant experiences, powerful production capability, consistent quality, diversified product portfolios and the control of the industry trend as well as our mature before and after sales services. We’d like to share our ideas with you and welcome your comments and questions.